Title NL101
Sample type RNA
 
Source name patient with normal liver
Organism Homo sapiens
Characteristics subject id: NL101
tissue: blood exosome
extraction date: 2012-12-11
gender: male
age (yrs): 61
height (cm): 167
weight (kg): 64
bmi: 22.9481157446
hbsag: (-)
anti-hcv: (-)
ast: 17
alt: 23
wbc: 3940
plt: 21.8
t_bil: 0.6
alp: 195
ggtp: 17
hb: 15.9
alb: 4.4
bs: 124
tg: 149
t_chol: 217
hba1c: 5.4
molecule subtype: microRNA
Treatment protocol Peripheral blood was collected from all subjects directly into serum tubes before anti-viral treatment. The tubes were centrifuged at 1,500 g for 10 min at 4℃, sera were aliquoted and additionally centrifuged at 2,000 g to completely remove any remaining cells. Sera were stored at -80℃ until use.
Growth protocol none listed
Extracted molecule total RNA
Extraction protocol Total RNA from 200 ul of serum was prepared using miRNeasy mini kit (Qiagen, Hilden Germany) according to the manufacturer’s instruction. Exosome rich fractionated RNA was prepared using Exoquick (System Biosciences, CA, USA). Briefly, 900 ul of serum was mixed with 250 ul of Exoquick and incubated for 12 hr at 4℃. The tubes were centrifuged at 1500 g for 30 min at room temperature and then supernatant was discarded. The pellet was dissolved with 200 ul of PBS with vigorous vortex. RNA was extracted using miRNeasy mini kit (Qiagen).
Label cy5
Label protocol To detect serum miRNA, 60 ng of RNA was labeled using the Human microRNA Microarray Kit (Rel 14.0) (Agilent Technologies, CA, USA) according to the manufacturer’s protocol (protocol for use with Agilent microRNA microarrays Version 1.0).
 
Hybridization protocol Labeled RNA was hybridized on microarray for 20hours at 55℃ by using the Human microRNA Microarray Kit (Rel 14.0) (Agilent Technologies, CA, USA) according to the manufacturer’s protocol (protocol for use with Agilent microRNA microarrays Version 1.0).
Scan protocol Hybridization signals were detected with a DNA microarray scanner G2505B (Agilent Technologies) and the scanned images were analyzed using Agilent feature extraction software (v9.5.3.1).
Description SAMPLE 68
Data processing Data were analyzed using the GeneSpring GX10.0.2 (Agilent). Quality control (QC) was applied according to the manufacturer’s instructions, and all data were approved by GeneSpring.
We used raw data (gProcessedSignal) and normalized each expression so as to have zero mean and unit sample variance.
 
Submission date Jun 06, 2016
Last update date Jun 20, 2023
Contact name Y-H. Taguchi
E-mail(s) tag@granular.com
Phone +81-3-3817-1791
Organization name Chuo University
Department Physics
Street address 1-13-27 Kasuga,Bukyo-ku
City Tokyo
State/province Non-US/Canada
ZIP/Postal code 112-8551
Country Japan
 
Platform ID GPL14943
Series (2)
GSE82301 Blood exsosomal miRNAs of patients with normal livers
GSE82303 Blood exsosomal miRNAs of patients with normal livers and liver disease patients

Data table header descriptions
ID_REF
VALUE normalized

Data table
ID_REF VALUE
3 105.6494
4 2.168969
5 45.37319
6 4.37099
7 13.52491
8 242.1467
9 8.655083
10 3.581038
11 6.297452
12 6.086792
13 15.78638
14 34.75069
15 3.623413
16 -5.106407
17 -2.461515
18 90.08061
19 4.249444
20 36.97295
21 193.8172
22 254.9118

Total number of rows: 14192

Table truncated, full table size 201 Kbytes.




Supplementary file Size Download File type/resource
GSM2188620_NL101.txt.gz 2.2 Mb (ftp)(http) TXT
Processed data included within Sample table

| NLM | NIH | GEO Help | Disclaimer | Accessibility |
NCBI Home NCBI Search NCBI SiteMap